Spotwave Wireless Ltd. SPOTCELL0006 Manuel D’Utilisation

Page de 50
Spotwave Wireless Inc.
9
3.2.1 Installing the DU
Three methods of positioning the DU (based on location) are outlined 
in the following procedure. Specifically they refer to installing inside 
buildings, on external walls, and on rooftops.
1.
Position the DU (but do not mount it) as close to the final desired 
mounting location as possible. The CU does not have to be in its 
final location while positioning the DU and it is helpful to have the 
CU near the DU.
2.
Connect the DU and CU with the enclosed cable. Tighten the cable 
to the DU and CU with a wrench (an 1/8th of a turn tighter than 
fingertight) to ensure moisture does not penetrate. 
3.
If installing the SpotCell 100: Connect the power supply wires to 
the CU by holding down the blue tabs and pushing the positive wire 
(marked with text) into the positive (+) side of the connector (see 
figure below). While still holding down the blue tab, push the 
remaining negative wire (identified by no text) into the negative (-) 
side of the connector. Release the tab to secure the power supply 
wires.
If installing the SpotCell 111/112: Simply connect the power 
supply as shown below.
Figure 3.1: Connecting power supply to CU
,QGRRUV
5RRI
([WHUQDOZDOO
While not strictly 
required, it is highly 
recommended the DU be 
installed facing a window 
when installed indoors.
The CU does not have to be in its 
final position at this time, but it 
should not be brought outdoors. 
SpotCell 100
power
connector
SpotCell 111/112
power
connector