Radwin Ltd. WINLINK Manuel D’Utilisation
Chapter 2 Initial Setup
AirMux-104 Installation and Operation Manual
2-4
Performing Initial Setup of AirMux-104
Configuring General Parameters
In order to establish communication link between manager station and
AirMux-104, you must select communication preference:
• Local (direct connection via cross cable)
• Network (connection via network to a specified IP address).
AirMux-104, you must select communication preference:
• Local (direct connection via cross cable)
• Network (connection via network to a specified IP address).
To change the communication preference:
1. In the Tools menu, select Preferences.
1. In the Tools menu, select Preferences.
AirMux Manager displays confirmation message for the communication
preference change (see
preference change (see
2. If you intend to change the communication preference change, click Yes.
The Communication Preferences dialog box appears (see
3. In the Communication Preferences dialog box, click Network, and enter the
RT IP address.
4. Click OK.
Figure 2-2. Confirmation Message for Communication Preference Change
Figure 2-3. Communication Preferences Dialog Box
To change general parameters:
1. In the Main menu, click Install Link.
2. The General Parameters dialog box appears (see
1. In the Main menu, click Install Link.
2. The General Parameters dialog box appears (see
3. From the General Parameters dialog box, select the following parameters:
Product type – select the AirMux-104 product type:
Low band (5.255 GHz to 5.345 GHz)
Mid band (5.470 GHz to 5.725 GHz)
High band (5.730 GHz to 5.850 GHz)
Currently AirMux-104 supports only the high band operation.
Note