Chapter 2  Initial Setup 
AirMux-104 Installation and Operation Manual 
2-4 
Performing Initial Setup of AirMux-104
 
 
Configuring General Parameters 
In order to establish communication link between manager station and 
AirMux-104, you must select communication preference:  
•  Local (direct connection via cross cable) 
•  Network (connection via network to a specified IP address). 
 
To change the communication preference: 
1.  In the Tools menu, select Preferences
AirMux Manager displays confirmation message for the communication 
preference change (see 
2.  If you intend to change the communication preference change, click Yes
The Communication Preferences dialog box appears (see 
3.  In the Communication Preferences dialog box, click Network, and enter the 
RT IP address. 
4. Click OK
 
Figure 2-2.  Confirmation Message for Communication Preference Change 
 
Figure 2-3.  Communication Preferences Dialog Box 
 
To change general parameters: 
1.  In the Main menu, click Install Link
2.  The General Parameters dialog box appears (see 
3.  From the General Parameters dialog box, select the following parameters: 
 
Product type – select the AirMux-104 product type: 
 
Low band (5.255 GHz to 5.345 GHz) 
 
Mid band (5.470 GHz to 5.725 GHz) 
 
High band (5.730 GHz to 5.850 GHz) 
 
Currently AirMux-104 supports only the high band operation. 
 