HydroPoint data systems inc. WT008 Manuel D’Utilisation

Page de 56
Reading from left to right, the lower line shows:
Wk1: -MTW-FS
Watering days for Week 1 (current week)
-10%
ADJUST setting 
Soak 15
Soak time
Note:
If increasing the irrigation by the ADJUST method exceeds the
maximum calculated cycle time, a cycle will need to be added and
the adjusted cycle time will be reduced. (The maximum cycle time
applies to an amount of water up to the runoff point due to soil
saturation.) 
For example, if the automatically calculated irrigation schedule
requires 4 minutes per cycle, 4 times per day for a total of 16 minutes,
and the user ADJUSTS irrigation to increase 20%, the new cycle time
will be 4.8 minutes (4 x 1.20). The total adjusted run time will be 19.2
minutes (4.8 x 4). If the maximum allowable cycle time to runoff is 4
minutes, the adjusted irrigation schedule will increase the number of
cycles to 5 and reduce the cycle run time to 3.7 minutes (i.e. 3.7 *
5=19.2).
Programming Your WeatherTRAK ET Plus
60