15.2 Power Cable
Use a cable with 18 AWG gauge (or thicker) wires to connect the PWR connector to
proper terminations that will connect to the DC source. Make sure the grounding pin is
connected to a solid grounding point. The connector on the MCU side is: Hirose
LF10WBRB-4P, On the Cable side it is: Hirose LF10WBP-4S.
proper terminations that will connect to the DC source. Make sure the grounding pin is
connected to a solid grounding point. The connector on the MCU side is: Hirose
LF10WBRB-4P, On the Cable side it is: Hirose LF10WBP-4S.
Figure 22: PWR Connector Front View (MCU-30 side)
MCU-30
LF10WBP-4S
Description
1
GND (-VDC)
2
Vin1 (+VDC)
3
Vin2 (+VDC)
4
GND (-VDC )