Gemalto M2M GmbH PDS6 Manuel D’Utilisation

Page de 36

PDS6_HIO_v02.800
Confidential / Preliminary
2014-10-27
Cinterion
® 
PDS6 Hardware Interface Overview 
2.1 Application Interface 
Page 14 of 35
 
 
 
2.1.4 
Analog Audio Interface 
PDS6  has  an  analog  audio  interface  with  a  balanced  analog  microphone  input  and  a  bal- 
anced  analog  earpiece  output.  A  supply  voltage  and  an  analog  ground  connection  are 
provided at dedicated pads. 
 
2.1.5 
Digital Audio Interface 
PDS6‘s digital audio interface (DAI) can be used to connect audio devices capable  of pulse 
code modulation (PCM). 
 
 
2.1.6 
GPIO Interface 
PDS6  offers  a  GPIO  interface  with  8  GPIO  lines.  The  GPIO  lines  are  shared  with  other 
interfaces  or  functions:  Fast  shutdown  (see 
Section  2.1.11.4
),  the  PWM  functionality  (see 
Section 2.1.9
), an pulse counter (see 
Section 2.1.10
). 
 
The following table shows the configuration variants for the GPIO pads. All variants are mutu- 
ally exclusive, i.e. a pad configured for instance as fast shutdown line is locked for alternative 
usage as GPIO. 
 
Table 2:  GPIO lines and possible alternative assignment 
 
GPIO
 
Fast Shutdown
PWM
Pulse Counter
 
GPIO2
 
 
 
 
GPIO4
 
FST_SHDN
 
 
 
GPIO5
 
 
 
 
GPIO6
 
 
PWM2
 
GPIO7
 
 
PWM1
 
GPIO8
 
 
 
COUNTER
 
GPIO9
 
 
 
 
GPIO10
 
 
 
 
 
 
After startup, the above mentioned alternative GPIO line assignments can be configured using 
AT commands (see 
[1]
). The configuration is non-volatile and available after module restart.