Huawei Technologies Co. Ltd BTS3812A-1900 Manuel D’Utilisation

Page de 118
NodeB LMT User Guide 
Chapter 9  Monitoring NodeB Performance and State in 
Real Time
 
Huawei Technologies Proprietary 
9-11 
Field  
Description  
MDB FileName 
z
 
To create a *.mdb file to save the test curve 
z
 
If it is blank, the system saves curve into the default file under 
the default directory. 
 
3)  Set parameters in the dialog box.  
4) Click 
OK.  
A dialog box prompts you whether to start the Rx frequency scanning.  
5) Click 
Yes.  
A monitor window is displayed showing the scanning curve. 
 
  Note: 
The scanning automatically stops when it reaches the end RF frequency.  
 
6)  Stop the test in either way below: 
z
 
Close the monitor window. 
z
 
Right-click the task in the task list below the graphical area. Click Delete Task on 
the shortcut menu to delete the task and curve. 
IV. Test Result Analysis  
The test result analysis of Rx frequency scanning is as follows:  
z
 
 If the NodeB is separated from the antenna and feeder system, the curve has 
jumps greatly higher than –108 dBm. This indicates that there must be internal 
interference of the NodeB. 
z
 
If the NodeB is connected to the antenna and feeder system with NTTA powered 
on, the curve has jumps greatly higher than –105 dBm. This indicates that there 
must be external interference of the NodeB. 
z
 
The shape of jumps tells the interference type in most cases: 
z
 
A triangular or trapezium jump: There are broadband interferences. The peak of 
the jump is the central frequency of the interference. 
z
 
A rectangle jump or a jump added with a rectangle: There is individual tone 
interference. The central point of the upper side of the rectangle is the interfering 
frequency. 
9.8  Testing MTRU Output Power 
I. Introduction  
The MTRU output power test measures the output power of the MTRU, including: