NodeB LMT User Guide 
Chapter 9  Monitoring NodeB Performance and State in 
Real Time
 
Huawei Technologies Proprietary 
9-13 
4) Click 
OK
A monitor window is displayed showing the service resource occupancy curve. 
5)  Stop the test in either way below: 
z
 
Close the monitor window. 
z
 
Right-click the task in the task list below the graphical area. Click Delete Task on 
the shortcut menu to delete the task and curve. 
IV. Test Result Analysis  
Once the test is started, the system reports the output power of the MTRU and each 
carrier every two seconds. 
9.9  Testing MTRU Temperature  
I. Introduction  
The MTRU temperature test measures the temperatures of the MTRU board and the 
internal power amplifier. 
II. Prerequisite 
None.  
III. Procedure  
Follow the steps below to test the MTRU temperature:  
1) Choose 
Maintenance Navigator -> Realtime State Monitoring. Right-click on 
the MTRU Temperature subnode.  
2) Click 
Create Monitor Task
The system displays the MTRU Temperature dialog box, as shown in Figure 9-7
 
Figure 9-7 MTRU Temperature dialog box 
Table 9-7 describes the fields of the MTRU Temperature dialog box.