Renishaw plc RMIV2 Manuel D’Utilisation

Page de 31
8
RMI visual diagnostics
3.
ERROR
Red
Error, other outputs may
be incorrect.
Off
No Error.
4.
SIGNAL
Green
Excellent communications.
Yellow
Good communications.
Red
Poor communications,
radio link may fail.
Off
No signal detected.
Green/off
Flashing: RMI is in
acquisition mode, and can
acquire a partner RMP.
Red/yellow
Flashing: RMI has (just)
acquired a new partner RMP.
Notes.
1.
The probe status LED will always be
illuminated when power is present.
There is no ‘power present’ LED/light.
2.
All the indicators report the status of the
partner RMP60. If there is no partner in
range, or the partner is off then the probe
status and error LEDs will be red and the
other LEDs will be off.
3.
When the RMI is powered it will enter the
acquire partner mode which will be indicated
by the flashing green signal LED (no change
in outputs). After a short time (~12 secs) it
will switch to its normal mode listening for
its partner.
4.
The conditions shown by the low battery,
probe status and error LEDs are the same
as those present on the electrical signal
outputs.