Renishaw plc RMIV2 Manuel D’Utilisation

Page de 31
11
RMI outputs
CAUTION:
Power supply voltage
Do not exceed 30 V between the black wire and the screen wire (green/yellow), or the
red wire and screen wire (green/yellow), or the red and black wires (power supply), as
this could result in permanent damage to the RMI and/or the customer power supply.
The use of in-line fuses at the machine cabinet end is recommended to provide
protection for the RMI and cable.
Screen connection
A good connection should be made to machine ground (star point).
Output stage circuit
Output stage supplies (+ve, –ve) should not be switched on and off to enable/disable
them as this can cause the over current protection to switch off the output completely.
Ensure that outputs from the RMI do not exceed specified current ratings.
!
RMI outputs
!
!