Senstar Corporation LM100 Manuel D’Utilisation
Installing the LM100 gateway
Senstar LM100 Product Guide
Page 27
10. Push the 2 crimps up into the shaft of the luminaire, ensure that both of the power cables have
drip loops and press the grommet into the bottom of the shaft.
11. Attach the power cables neatly to the fence with UV resistant cable ties (P/N GH0916 - 1000
pieces) and continue making the power connections.
Installing the luminaire AP
The luminaire AP is usually attached to the same post as the gateway device. Mount the luminaire
AP in the same manner as the standard luminaires. The luminaire AP includes a 3 m (10 ft.) power
and data cable which is connected to the gateway device.
AP in the same manner as the standard luminaires. The luminaire AP includes a 3 m (10 ft.) power
and data cable which is connected to the gateway device.
shows an installed luminaire
AP and the AP connections to the gateway. See
and
for
additional installation and connection details.
Installing the LM100 gateway
The gateway is shipped with two stainless steel clamps that are used for securing the enclosure to
a post (OD 4.5 to 12.7 cm). The hardware required to mount the enclosure on another type of
surface is customer-supplied.
a post (OD 4.5 to 12.7 cm). The hardware required to mount the enclosure on another type of
surface is customer-supplied.
illustrates the gateway features and
shows a fence-mounted gateway.
Figure 26: Power connection crimp tools
Figure 27: Luminaire AP mounting and connection
Note
The LM100 gateway can be installed up to 100 m (328 ft.) away from
the luminaire AP by splicing in a length of suitable power and data
cable. In this case, the 3 m cable that comes with the luminaire AP must
be shortened so the data and power splices can be fitted into the
luminaire AP’s shaft. Alternately, an outdoor-rated electrical junction box
can be used to protect the splice.
the luminaire AP by splicing in a length of suitable power and data
cable. In this case, the 3 m cable that comes with the luminaire AP must
be shortened so the data and power splices can be fitted into the
luminaire AP’s shaft. Alternately, an outdoor-rated electrical junction box
can be used to protect the splice.
cable shield
RS-485
A B
DC power
_ +
luminaire AP