Garmin International Inc 0181200 Manuel D’Utilisation

Page de 68
GRA 5500 Installation Manual
190-01277-00
Page 2-12
Rev. A
Figure 2-5  Coaxial Cable Requirements
TNC male connectors are required to build the coaxial cable assemblies and are not provided with the 
GRA 5500 system.  
 provides guidance information concerning cable types, cable type 
attenuation, and cable type lengths in agreement with the overall requirements for the coaxial cable 
assemblies.  The maximum coaxial cable lengths in 
 are for reference only and are defined as the 
end-to-end cut cable length (non-terminated cable lengths).  Actual cable lengths may vary depending on 
the manufacturer specifications and recommendations for the specific coaxial cable and connectors 
(
 references common sources for cable and connector part numbers. 
 
 shows suggested installation instructions for typical TNC connectors.
5.0 dB maximum attenuation, VSWR <1.5:1
30 feet maximum length, 1 foot minimum length
GRA 5500
RX Port
5.0 dB maximum attenuation, VSWR <1.5:1
30 feet maximum length, 1 foot minimum length
GRA 5500
TX Port
DRAFT