Garmin International Inc 0181200 Manuel D’Utilisation

Page de 68
190-01277-00
GRA 5500 Installation Manual
Rev. A
Page 2-13
Figure 2-6  TNC Connector Installation
NOTE
It is recommended that a two inch piece of adhesive heat shrink tubing be installed over 
all coaxial cable interfaces. The heat shrink tubing should overlap the connector body as 
much as practical without interfering with the coupling nut (see Figure 2-7).
Figure 2-7  Heat Shrink Positioning
NOTE
It is recommended that the nominal end-to-end coaxial cable (non-terminated) length for 
each assembly be recorded for the specific installation in the event that a particular 
coaxial cable assembly associated with an installed set should require replacement.
Connector
Body
Ferrule
Coaxial Cable
Heat shrink not to protrude past 
this surface.
DRAFT