LC 1200 Manual                                                                                                                   The LC unit 2-1 
The LC unit 
  Specifications 
  Positioning 
  Mounting 
  Wiring 
  A Look Inside 
  Tamper Switch adjustment 
  Tuning 
 
Specifications 
  Power Requirements 
  Temperature 
  Weight 
  Location 
Power Requirements 
  12V DC 
  0.5A for one 3101 Magnetic Lock 
1.0A for two 3101 Magnetic Locks 
1.0A for one 3000 Magnetic Lock  
Temperature 
The LC unit and its associated peripherals 
operate best in an ambient temperature between 
35 and 90 degrees Fahrenheit. Operation outside 
of this range may cause unexpected or 
undesirable results, including premature 
component or device failure. 
Weight 
The LC unit weighs approximately 1 U.S. 
pounds, which should be considered when 
choosing mounting location and hardware. 
Positioning 
The recommended location of the LC unit is on 
the latch side of the door with its lowest point 
about 2 feet above the floor (Figure 2.1) 
Mount the LC unit at least 3 inches away from 
any type of metal including: 
  metal door frames 
  metal studs 
  metal lathe walls 
  metal electrical box 
  metal conduit 
  metal pipes 
In addition, the LC unit should be positioned 
within 18” maximum of the monitored door or 
elevator to assure proper coverage. The 
recommended distance is 3 to 6 inches.  
Positioning the LC unit correctly will help in 
avoiding unintended activation of a Tag in a 
nearby room or a passerby. The goal is to 
produce a Tx Activation Field that adequately 
covers the doorway but does not extend into 
nearby rooms.  
Figures 2.1 through 2.4 show the recommended 
location of the equipment in a typical door, 
double door, elevator, and hallway application. 
Use them for reference during installation.