Appendix A - Serial Ports
81
Serial port 1 can be configured for either RS-232 or TTL signal levels. The signal
level selection is controlled with internal jumper plugs (see Appendix F - Internal
Jumper Block).
The RS-232 standard defines minimum and maximum voltage levels for the
drivers and receivers. However, in practice the drivers and receivers work
correctly with signal levels that are different from the specification.
level selection is controlled with internal jumper plugs (see Appendix F - Internal
Jumper Block).
The RS-232 standard defines minimum and maximum voltage levels for the
drivers and receivers. However, in practice the drivers and receivers work
correctly with signal levels that are different from the specification.
Level (volts DC)
Type Low
High
Drivers (into a 3k to 7k ohm load)
RS-232 Specification
Actual TS4000 Drive Levels
Actual TS4000 Drive Levels
-15 to -5
-9 to -6
+5 to +15
+6 to +9
Receivers (with 3k to 7k ohm load)
RS-232 Specification
Actual TS4000 Receive Levels
Actual TS4000 Receive Levels
-25 to -3
-25 to +0.8
+3 to +25
+2.4 to +25
Level (volts DC)
Type Low
High
Output (Driver)
0.0 to +0.4
(sinking up to 4 mA)
(sinking up to 4 mA)
+3.0 to +5.0
(sourcing up to 4 mA)
(sourcing up to 4 mA)
Input (Receiver)
-25 to +0.8
+2.4 to +25
(3k to 7k ohm load)
The signal polarity is the same for both RS-232 and TTL operation.
Level State
Voltage Low
Mark
Control signal inactive
Stop bit state (end of async character)
Logic one data bit state (within async character)
Control signal inactive
Stop bit state (end of async character)
Logic one data bit state (within async character)
Voltage High
Space
Control signal active
Start bit state (beginning of async character)
Logic zero data bit state (within async character)
Control signal active
Start bit state (beginning of async character)
Logic zero data bit state (within async character)
Signal Levels
RS-232 Signal Levels
TTL Signal Levels
Signal Polarity