5.1.3.3. Netstat 
Use Netstat to see the actual connection 
status of NetCom. This is a standard tool for 
network debugging. 
 
A “Foreign Address” of 0.0.0.0 is listed when NetCom is waiting for an 
incoming connection (
LISTEN
). If the value is not 0.0.0.0, the 
connection is either active (
ESTABLISHED
) or closed (
TIMEWAIT
). 
 
Image 41: Web Panel Start Netstat 
Update 
Proto Local Address         Foreign Address       State       
tcp   0.0.0.0:23            0.0.0.0:0             LISTEN      
tcp   0.0.0.0:80            0.0.0.0:0             LISTEN      
tcp   0.0.0.0:2000          0.0.0.0:0             LISTEN      
tcp   0.0.0.0:2001          0.0.0.0:0             LISTEN      
tcp   0.0.0.0:2010          0.0.0.0:0             LISTEN      
tcp   0.0.0.0:2011          0.0.0.0:0             LISTEN      
tcp   0.0.0.0:2020          0.0.0.0:0             LISTEN      
tcp   0.0.0.0:2021          0.0.0.0:0             LISTEN      
tcp   0.0.0.0:2030          0.0.0.0:0             LISTEN      
tcp   0.0.0.0:2031          0.0.0.0:0             LISTEN      
tcp   192.168.1.243:80      192.168.1.42:1280     TIMEWAIT    
tcp   192.168.1.243:80      192.168.1.42:1281     ESTABLISHED 
udp   0.0.0.0:161                                             
udp   0.0.0.0:19970                                           
udp   192.168.1.243:32331                                     
Image 42: Web Panel Netstat Output 