Itron Inc. 100THONA Manuel D’Utilisation

Page de 34
Mounting the 100T-HON Telemetry Module 
 
 
TDC-1346-000 100T-HON Honeywell Telemetry Module Installation Guide 
12 
 
Proprietary and Confidential
 
 
 
 
2.  Slide the module up onto the adapter plate mounting lug until the mounting lug (1) is as far as possible 
inside the module mounting lug recess (2).  
 
3.  Align the module back plate mounting holes with the pipe mount adapter plate holes. Install the two one-
inch mounting screws from the installation kit.  
 
4.  Tighten the module mounting screws evenly in an alternating fashion. Torque the screws to 9 - 12 inch-
pounds of pressure. 
 
Mounting the 100T-HON Telemetry Module on a Wall or Other Flat Vertical 
Surface 
 
 
Note  For easier installation, drill three pilot holes in the mounting surface (use the correct size drill bit to 
accommodate the module mounting screws [see the drilling template below]). The drilled pilot holes for 
the two bottom screws must be on a horizontal line. To mount the module on a sheet metal surface, use 
the mounting screws included with the Mounting kit. Use a comparable wood screw to mount the module 
on a vertical wood surface.  
Carefully select a mounting location free from electrical wires. The mounting location must have the 
proper clearance to accommodate the 1-1/2-inch module mounting screws so nothing is damaged by the 
drill or mounting screws. 
 
Module drilling template 
A  3 inches 
B  1-11/16 inches 
C  3-3/8 inches