45-degree angle with the
pipe running to the right
45-degree angle with the pipe
running to the left
Horizontal
Selecting a wall or flat vertical mounting location
Carefully select a mounting location free from electrical wires. The mounting location must
have the proper clearance to accommodate the 1-1/2-inch module mounting screws so
nothing is damaged by the drill or mounting screws. Use a compatible mounting screw.
1. Drill three pilot holes in the mounting surface.
The drilled pilot holes for the two bottom screws
must be on a horizontal line.
1. 3 inches
2. 1-11/16 inches
3. 3-3/8 inches
2. Screw the top mounting screw into the top pilot
hole drilled in step one, leaving enough of the
screw protruding so the ERT module lug recess
on the back plate slides over the screw head and
fits completely into the lug recess. Make
adjustments as necessary.
3. Install the two bottom mounting screws.
Tighten the screws in an alternating pattern to
secure the module firmly in position.
4. Place a new tamper seal over each bottom
ERT module mounting screw as required.
Mounting the Remote 500G ERT Module
OpenWay Riva 500G Gas ERT Module Installation Guide, Remote Mount TDC-1678-000
12
Proprietary and Confidential