Itron Inc. 500GR Manuel D’Utilisation

Page de 76
18. Align the index wriggler with the meter's drive
dog. Install the index on the meter using the
index mounting screws. Tighten one index screw
two turns. Install and tighten the remaining index
screw. Tighten the first index mounting screw
completely (alternating fashion).
19. Install a strain-relief cable tie about 1-1/4-inch from the encoder cable's stripped end. The cable
tie must be inside the index cover after the cover is installed on the meter. Remove any excess
cable tie with a side-cutting pliers and dispose the excess cable tie.
20. Remove the protective backing on the
replacement gasket to expose the adhesive side
of the gasket. Align the gasket (1), encoder cable
(2), and cable tie (for strain-relief) (3) on the
meter as shown.
Caution: Route the encoder cable inside the index cover to provide strain relief
(minimize pulling or twisting on the encoder). Verify that the strain-relief cable tie on the
encoder cable is inside the index cover when the cover is installed on the meter. The
gasket must align with the index cover screw holes and adhere to the meter face to
insure a proper seal after the index cover is installed.
21. Install the four index cover screws and
tighten just enough to hold the screws in place.
Diaphragm Meter Installation
OpenWay Riva 500G Gas ERT Module Installation Guide, Remote Mount TDC-1678-000
68
Proprietary and Confidential