TransCore 05716 Manuel D’Utilisation

Page de 210
Commands
7-25
ing is disabled with command #6170, the reader does not echo the command, but 
only transmits its response. The reader never echoes while in ECP or download mode 
operation.
Reader response:
Done
6171 Enable Echo Mode (Factory Default)
Command #6171 enables the reader to echo received host commands. Command 
#6170
 disables echo mode.
Reader response:
Done
 
63 Reset Reader
Command #63 resets the power fail bit, clears all buffers, resets tag uniqueness, turns 
off both output lines, transmits the sign-on message, and returns to the data mode.
Note:  This command does not reset any other configuration parameters. 
Reader response:
Model E4 Series Ver X.XX SNYYYYYY
Copyright 2008 TransCore
where
X.XXD
Version number
YYYYYY
Serial number of the unit, skipping the fourth character printed on 
the reader product label.
640N RF Control
Command #640N directly controls the RF module. The N value controls the RF 
power as shown in 
.
Note:  These commands only have an effect when the reader is not in MPRR mode. 
See commands #836 and #837.
Command #6400 disables RF-by-input control command #641 Select RF-by-Input 
Control.
Table 7-9  RF Control Commands
Command
RF Power
6400
Turns off RF
6401
Turns on RF
6402
Turns on continuous wave (CW) RF until 
command 6400 or 641 is received by the 
reader.