TransCore 05716 Manuel D’Utilisation
Encompass 4 Reader System Guide
7-32
characters to be entered. When setting the serial number, skip the fourth (middle)
character of the seven-character number shown on the reader product label.
character of the seven-character number shown on the reader product label.
Note: Once assigned, the serial number is preserved during power-down and the
loading of default parameters.
loading of default parameters.
Reader response:
Done
696S...S Store Hardware Configuration String
Command #696S...S stores hardware configuration information into reader mem-
ory.
ory.
The hardware configuration string is assigned according to the following format:
696S...S
where S...S is the hardware configuration string that may contain as many as 20
uppercase or lowercase ASCII alphanumeric characters.
uppercase or lowercase ASCII alphanumeric characters.
Note: Once assigned, configuration information is preserved during power-down and
the loading of default parameters.
the loading of default parameters.
Reader response:
Done
Auxiliary Reader Control — Command Group 8
Group 8 commands provide control of reader functions, such as the sense input lines.
8110
Command #8110 turns on RF port0, sends the command on Ctag pin 0 to fire off
Ctag address 0.
Ctag address 0.
8111
Command #8111 turns on RF port1 and sends the command on Ctag pin 0 to fire off
Ctag address 1.
Ctag address 1.
8112
Command #8112 turns on RF port2 and sends the command on Ctag pin 1 to fire off
Ctag address 0.
Ctag address 0.
8113
Command #8113 turns RF port3 and sends the command on Ctag pin 1 to fire off
Ctag address 1.
Ctag address 1.
8142X
Command #8142X sends the command on Ctag pin 0 to set the Ctag character.