2-10
Electrical Power
A dedicated electrical power supply must be present at the site and available to the 
MPRR at all times. The power must be 16-20V AC or 16-28V DC. A step-down trans-
former is available (North America only) to convert a 120V AC duplex wall outlet 
with ground to 18V AC, as is a step-up transformer to convert a low-voltage 12V AC 
outlet to 18V AC. Consult your local and national electrical codes for installation and 
safety requirements.
Note:  MPRRs installed outside North America require a locally supplied transformer. 
If 18V AC or 18V DC power is available, the transformer option is unnecessary.
TransCore offers a Class C transformer accessory kit (part number 76-1620-005) for 
sites where 110V AC is available. It is the installer’s responsibility to supply conver-
sion equipment and wiring for other voltages. 
 contains power supply current 
requirements.
Power circuits are protected internally against power surges. 
Host Communications
Your site design must include communications between the MPRR and a host device. 
The MPRR communicates with the host device through an asynchronous serial line. 
This serial line is an RS
232 interface. 
 shows the MPRR communications 
port and 
 shows the connector pin designations.
Table 2-2  Connector Cabling Accessory Kits
Part Number
Description
58-7001-001
MPRR-to-TRU six-foot cable assembly
58-7001-002
MPRR-to-TRU 20-foot cable assembly
58-7001-003
MPRR cable assembly, no TRU
Table 2-3  Power Supply Current Requirements
Supply
(RF On)
Worst Case 
Maximum Current at 
68°F (20°C)
(RF Off)
Standby Operating 
Current at 68°F 
(20°C)
16 to 20V AC
1.7 A at 18V AC
1 A at 18V AC
16 to 28V DC
1.7 A at 18V DC
1 A at 18V DC