TransCore 05716 Manuel D’Utilisation

Page de 210
Multiprotocol Rail Reader System Guide
4-4
Installation Accessory Options
 lists optional TransCore MPRR installation accessory items.  
Additional Materials Needed for Testing
You need these additional materials to perform the pre-tests on the MPRR:
Test tags, supplied by the TransCore dealer or distributor
Suitable 16 to 20V AC or 16 to 28V DC power wiring for the MPRR 
Audible circuit tester and 9V DC battery for circuit tester power 
Wire stripper
At least one MPRR-compatible antenna
Suitable RF interface coaxial cable
Pre-installation Testing of the MPRR
Before installing the MPRR permanently at the site, you should use an audible circuit 
tester to confirm that the MPRR has power and can read a tag presented in the tag read 
zone.
Testing the MPRR Using an Audible Circuit Tester
An audible circuit tester is also called a buzz box. These boxes are available at some 
electronic parts supply stores, or you can make a buzz box, as shown in 
The buzz box is powered by a 9V DC battery and is equipped with two alligator-clip 
leads. When you touch the leads together, the box makes an audible sound.
Table 4-1  Installation Accessories
Part No.
Description
58-7001-001
MPRR-to-Train Recording Unit (TRU) six-foot cable assembly
58-7001-002
MPRR-to-TRU 20-foot cable assembly
58-7001-003
MPRR cable assembly, no TRU
20-7001-001
MPRR check tag accessory kit