Encompass 4H Reader System Guide
7-34
Command #6400 disables RF-by-input control command #641 Select RF-by-Input 
Control.
Reader response:
Done
641 Select RF-by-Input Control (Factory Default)
Command #641 configures the reader for RF-by-input control. The reader automati-
cally turns on RF when it detects a presence through sense0. The reader turns off RF 
according to the selected RF control algorithm (#692N Select RF Control Algorithm).
Reader response:
Done
643NN Select ATA Operating Range (Distance)
Command #643NN selects the read range for ATA tags where NN is a hexadecimal 
value from 00 to 1F; the range increases with increasing NN value. The range can be 
adjusted for 32 discrete values where 00 is the shortest range and 1F is the longest 
range. The default range value is 1F.
Reader response:
Done
644NN Set RF Attenuation 
Command #644NN sets the attenuation control for the output RF power where NN is 
a hexidecimal value from 09 to 0F. Settings for attenuation are 1.0 dB increments over 
a range of 6 dB of attenuation from the maximum power setting of 24 dBm at 0-dB 
attenuation to a minimum power level of 18 dBm.
The Set RF Attenuation command NN variables and corresponding attenuation set-
tings are shown in 
Table 7-14  RF Attenuation Command Variables 
Variable (NN)
Attenuation 
Setting (dB)
09
0
01
1
02
2
03
3
04
4
05
5
0F
6