Commands
7-37
in all readers. In this example it is determined that an IAG attenuation setting of 6 dB 
(#64606) prevents a reader from activating a tag in an adjacent lane.
Table 7-15  Example of Encompass 4H Reader Plaza Synchronization Bus Settings
Reader Lane
Set Synchronization Output Delay Time 
(#648NN)
Set Synchronization Hold-Off Time 
(#649NN)
1*
#64814 = 20 ms synchronization time
#64901 = 1 ms hold off
2
#64816 = 22 ms synchronization time
#64902 = 2 ms hold off
3
#64818 = 24 ms synchronization time
#64903 = 3 ms hold off
4
#6481A = 26 ms synchronization time
#64904 = 4 ms hold off
5
#6481C = 28 ms synchronization time
#64905 = 5 ms hold off
* Reader 1 becomes the bus synchronization master.
65 Reset Power Fail Bit
Command #65 resets the power fail bit to 0. The bit changes from 0 to 1 when power 
is restored to the reader. Upon reader power-up, the host transmits either command 
#65
 or #63 Reset Reader to properly initialize this bit. The current state of the power 
fail bit may be displayed. Refer to 
 for 
more information.
Reader response:
Done
66F Load Default Operating Parameters
Command #66F loads all the factory default operating parameters except RF operat-
ing frequency. Refer to 
tings” 
for a listing of the defaults.
Reader response:
Done
 
All parameters loaded OK
Error
 
A parameter load failed
67N Set Output Pulse Duration
Command #67N sets the output pulse duration for the command #621 Predefined 
Output Control. This command specifies the length of time that output line(s) will be 
asserted upon receipt of a valid and unique tag ID. The factory default setting is 228 
ms. The variable N specifies an output pulse duration of 48 ms to 752 ms.
Uppercase or lowercase characters are allowed for N; for example, hex digits A 
through F or a through f. The command numbers and corresponding output pulse 
durations are shown in