Commands
7-41
preted as an open circuit. This feature allows greater flexibility in the attachment of 
external equipment to the reader inputs. For example, some proximity sensors indicate 
presence with an open circuit. In this instance, command #6941 can enable input 
inversion so that an open circuit input indicates a presence. The values for N represent 
the two inversion options as shown in 
.
 
Table 7-20  Input Inversion Options
Command
Option
6940
Disable input inversion (factory default)
6941
Enable input inversion
Reader response:
Done
695S...S Set Serial Number
Command #695 assigns the reader serial number according to the format:
695SSSSSS
where SSSSSS is the serial number.
The serial number may contain as many as six uppercase or lowercase ASCII alphanu-
meric characters. 
Note:  The factory-assigned serial number of the reader contains seven characters. 
However, to maintain backward compatibility, the reader software allows only six 
characters to be entered. When setting the serial number, skip the fourth (middle) 
character of the seven-character number shown on the reader product label.
Note:  Once assigned, the serial number is preserved during power-down and the 
loading of default parameters.
Reader response:
Done
696S...S Store Hardware Configuration String
Command #696S...S stores hardware configuration information into reader mem-
ory.
The hardware configuration string is assigned according to the following format:
696S...S
where S...S is the hardware configuration string that may contain as many as 20 
uppercase or lowercase ASCII alphanumeric characters.
Note:  Once assigned, configuration information is preserved during power-down and