TransCore 0596465PT15 Manuel D’Utilisation

Page de 276
Troubleshooting and Maintenance
9-3
Chapter 9
Troubleshooting and Maintenance
This chapter contains information for troubleshooting an Encompass
®
 
4H Reader and performing minimal maintenance checks. It also includes 
information for returning products for repair, obtaining support, and 
contact information for providing feedback and suggestions to 
TransCore. 
Error Messages
The Encompass 4H Reader transmits an error message if a command received from 
the host is not a recognized command or if information supplied with the command is 
not correct. The reader sends this message to diagnostic commands if the reader fails 
the specified test.
Table 9-1 Error Messages  
Error 
Message
Description
Corrective Action
Error07
The RF phase locked loop (PLL) has lost 
lock and is unable to operate at its 
intended frequency. RF output is disabled 
while the Encompass 4H Reader attempts 
to reset the PLL.
Reset the reader if error persists.
Error08
The RF PLL has successfully regained 
lock and has been reset to its proper 
operating frequency. The RF section is 
returned to its state prior to losing lock 
(enabled/disabled). Error08 will only be 
issued after Error07 has been issued.
No action necessary; the previous error 
has been corrected.
Error11
The operator is attempting to use an 
Intellitag-based tag in Wiegand mode while 
the Encompass 4H Reader is in ID-only 
mode, thus Wiegand compatibility issues.
Enable eATA mode using command #489 
if Wiegand operation is needed and the 
tags are programmed with Wiegand data.
ErrorRF1
Warning message that the RF board did 
not return an update acknowledge signal
If the reader indicates a single 
ErrorRF1
 
event and recovers from the error, no 
corrective action is required. You may want 
to track this error message if it should 
occur again. If the reader indicates 
repeated 
ErrorRF1
 warning messages 
then return the reader to the factory.