TransCore 0596465PT15 Manuel D’Utilisation

Page de 276
Installing the Encompass 4H Reader
4-19
9.
Mount the Encompass 4H Reader to the pole-mount bracket using Allen screws, 
as shown in 
Figure 4-12  Connecting the Encompass 4H Assembly to Pole Mount Bracket
10. Adjust the assembly by pointing the Encompass 4H Reader to the middle of the 
area where tags will be read and tighten all screws and straps slightly.
Note:  Adjust the Encompass 4H Reader to provide the most direct line of sight to the 
tags.
Caution
To ensure reliable reader operation, TransCore strongly advises that you follow the 
National Electric Code for lightning protection for the locale where you are install-
ing the Encompass 4H Reader.
After mounting the Encompass 4H Reader, you must connect it to a dedicated 16 to 
20V AC or 16 to 28V DC power supply.
Connecting the Power Supply
To connect the Encompass 4H Reader to a low-voltage AC power supply follow the 
procedures described previously in the section 
.
To connect the Encompass 4H Reader to a low-voltage DC power supply follow the 
procedures described previously in the section 
.