Rosslare Enterprises Ltd AYC-E60 Manuel D’Utilisation

Page de 73
Reader Functionality 
AYC-E/Q60 Family Instruction Manual 
27 
5.2.4.4
  Option 4: 4 Keys Binary + Facility Code, Wiegand 26-
Bit 
This option buffers 4 keys and outputs keypad data with a 3-digit 
Facility code like a standard 26-bit card output. 
The Facility code is set in Programming Menu 4 and can be in the 
range 000 to 255. The factory default setting for the Facility code is 
000 (see Sectio
 5.2.8 for more information). 
The keypad PIN code is 4 digits in length and can range between 
0000 and 9999. On the fourth key press of the 4-digit PIN code, the 
data is sent across the Wiegand Data lines as binary data in the same 
format as a 26-bit card. 
If the "*" key or the "#" key are pressed during PIN code entry, the 
keypad clears the PIN code entry buffer, generates a beep, and is 
ready to receive a new 4-digit keypad PIN code. 
If the entry of the 4-digit keypad PIN code is disrupted and no number 
key is pressed within 5 seconds, the keypad clears the PIN code entry 
buffer, generates a beep, and is ready to receive a new 4-digit keypad 
PIN code: 
(EP) FFFF FFFF AAAA AAAA AAAA AAAA (OP) 
Where: 
EP = Even parity for first 12 bits 
OP = Odd parity for last 12 bits 
F = 8-Bit Facility code 
A = 16-Bit code generated from keyboard 
5.2.4.5
  Option 5: 1 to 5 Keys + Facility Code, Wiegand 26-Bit 
Option 5 buffers up to 5 keys and outputs keypad data with a Facility 
code like a 26-bit card output. 
The Facility code is set in Programming Menu 4 and can be in the 
range 000 to 255. The factory default setting for the Facility code is 
000 (see Sectio
 5.2.8 for more information). The keypad PIN code 
can be one to five digits in length and can range between 1 and 
65,535. When entering a keypad PIN code that is less than 5 digits in