Only one keypad transmission format can be active at any one
time.
•
When using the keypad transmission format "1 to 8 keys BCD,
Clock & Data" (Option 8) an additional input is required to
specify the number of keys in the PIN code.
specify the number of keys in the PIN code.
5.2.4
Keypad Transmission Format Option Number
See Table 3 to determine the Option Number for the Keypad
Transmission Format you wish to select.
Transmission Format you wish to select.
Table 3: Keypad Transmission Format
Keypad Transmission Format
Option Number
Single Key, Wiegand 6-Bit (Rosslare Format)
1*
Single Key, Wiegand 6-Bit with Nibble + Parity Bits
2
Single Key, Wiegand 8-Bit, Nibbles Complemented
3
4 Keys Binary + Facility code, Wiegand 26-Bit
4
1 to 5 Keys + Facility code, Wiegand 26-Bit
5
6 Keys BCD and Parity Bits, Wiegand 26-Bit
6
Single Key, 3x4 Matrix Keypad
7
1 to 8 Keys BCD, Clock & Data Single Key
8
Single key, Wiegand 4-Bit
9
* Option 1 is the default factory setting.
More information on each of the different keypad transmission
More information on each of the different keypad transmission