Rosslare Enterprises Ltd AYC-E60 Manuel D’Utilisation

Page de 73
Controller Functionality 
66 
AYC-E/Q60 Family Instruction Manual 
5.
  The Mode LED flashes green. 
 
6.
  Enter the assignment digit for the current user slot: 
 
“1” activates the Lock Strike relay only default 
 
“2” activates the Auxiliary relay only 
 
“3” activates the Lock Strike and Auxiliary relays 
If the assignment digit is valid, three beeps are heard and the 
controller returns to Normal mode. 
If the assignment digit is invalid, a long beep sounds and the 
controller waits for another assignment digit to be entered. 
6.10.17
  PIN Code Length/Factory Default Settings 
 
You must be very careful before using this command! 
Changing the PIN code length also erases the entire 
memory contents, including all user and special codes, and 
return all codes to their factory-default settings. 
 
1.
  Enter Programming mode. 
 
2.
  Select the desired PIN code length as follows: 
 
00 – Returns to factory defaults and sets a 4-digit code. 
 
05 – Returns to factory defaults and sets a 5-digit code. 
 
06 – Returns to factory defaults and sets a 6-digit code. 
 
08 – Returns to factory defaults and sets a 4-8 digit code 
Note:  When choosing the 4-8 option, please note that you 
should either enter zeros before the code, or press 
pound at the end (for example if your code is 
12345
enter either 
00012345 or 12345#). 
Both the Mode and Door LEDs 
flash red. 
 
3.
  Enter your 4- to 8-digit 
Programming code. 
 
Mode/Transmit 
 
Door/Program 
 
Green
 
Orange
 
Mode/Transmit 
Door/Program 
Red
 
Red
 
Mode/Transmit 
Door/Program 
 
Green