If the Programming code is valid, all memory is erased. You hear 
three beeps and the controller returns to Normal mode. 
If the Programming code is invalid, you hear a long beep and the 
controller returns to Normal mode without erasing the memory 
contents. 
6.10.18
  Replacing a Lost Programming Code 
 
The  AYC-E/Q60 must be in Normal mode; otherwise, this 
does not work. Make sure that the Mode LED is green 
before proceeding. 
1.
  Remove power from the Power Supply Unit. 
2.
  Press the REX button on the Power Supply Unit. 
3.
  Apply power to the unit with REX button pressed. 
4.
  Release the REX button. 
5.
  You now have 15 seconds to program a new Programming code 
into the Access Control unit using the default code based on the 
PIN code length you chose (see Table 4) before the controller 
reverts to the existing code. 
6.10.19
  Replacing a Lost Normal/Secure Code 
 
The  AYC-E/Q60 must be in Secure mode; otherwise, this 
does not work. Make sure that the Mode LED is red before 
proceeding. 
1.
  Remove power from the Power Supply Unit. 
2.
  Press the REX button on the Power Supply Unit. 
3.
  Apply power to the unit with the REX button pressed. 
4.
  Release the REX button. 
5.
  You now have 15 seconds to program a new Normal/Secure code 
into the Access Control unit using the default code based on the 
PIN code length you chose (see Table 4) before the controller 
reverts to the existing code.