HARRIS CORPORATION WM4900CL Manuel D’Utilisation

Page de 45
MM-018965-001 
 
36 
7.4.1 
Installing an Omnidirectional Antenna 
An omnidirectional antenna may be mounted directly to the Client using the following procedure: 
1.  Connect an N-type male to male RF adapter (not included) to the omnidirectional antenna.  Hand-
tighten the connector. 
2.  For Copper Clients, external lightning protection is required to provide maximum protection to the 
site.  Connect the optional lightning suppressor to the antenna assembly as shown in Figure 7-2.   
A list of approved surge protection devices can be found in the VIDA Broadband Installation Manual, 
MM-014720-001.
 
3.  Connect the completed antenna assembly to the Client antenna connector. 
 
Figure 7-2: VIDA Broadband Client Antenna with External Lightning Protection 
7.4.2 
Installing a Directional Antenna 
A directional antenna can be mounted directly on the unit using the optional universal mounting bracket 
kit.  After the universal mounting bracket is attached, it can be adjusted to point the forward beam pattern 
of the antenna in the direction needed for network connectivity.  Refer to the VIDA Broadband 
Installation Manual, MM-014720-001
 for alignment instructions. 
Four mounting holes are provided for mounting an antenna to the front cover housing of the subscriber 
stations.  These mounting holes are spaced at a 1.772" x 5.118" (45 mm × 130 mm) rectangular pattern 
tapped to accept 1/4-20 UNC-2B hardware with a minimum hole depth of 0.31".   
A low loss RF cable (not included)  is needed to connect between the unit’s antenna connector and the 
directional antenna.  The RF cable and connectors must be capable of passing frequencies up to 5.2 GHz 
with minimal loss.