Tyco Safety Products/Sensormatic AMS1080 Manuel D’Utilisation

Page de 18
 
AMS-1080 DETECTION SYSTEM 
8200-0418-01, REV. A 
INSTALLATION AND SERVICE GUIDE 
12 of 18
 
Controller Installation 
Tools required: 
- Tape 
measure 
-  Pencil or marker 
-  Electric drill and drill bits: 5.5mm (7/32in) and 9.5mm 
(3/8in) 
-  Phillips-head screwdriver or bit 
-  Hand vacuum or broom 
Parts required:  
Install Kit 0352-0203-01 
Screw, self-drilling, M4, 8x25, PHP 
5899-0031-01 
PROCEDURE 
1.  Set the controller on a shelf or mount it, with its 
fan facing down, to a vertical surface using the 
four self-drilling screws supplied. 
WARNING! 
The vertical surface must 
be able to support 13.3kg (29.4 lbs). 
 
2.  Referring to the diagram on page 4, attach 
connectors to cables used for the installation. 
3.  Plug cables into the appropriate  
connectors on the controller. 
AC Hookup 
CAUTION: Fan voltage is factory set 
for 240Vac. 
If using 120Vac, remove the 
cover from the controller and change fan 
jumpers to 120Vac. See label inside the 
controller for jumper locations. 
PROCEDURE 
1.  Choose a power cord for the country of use. 
Power cords come in .9m (3ft), 2.7m (9ft), 3.7m 
(12ft), and 4.6m (15ft) lengths. 
2.  Plug in the power cord. The controller 
automatically senses the voltage (100-120Vac 
or 200-240Vac). No adjustments are required. 
WARNING—RISK OF ELECTRIC 
SHOCK! 
The ac power cord may carry 
120Vac or 240Vac. 
CAUTION: When using a power cord, 
a socket-outlet must be installed near 
the controller and in an easily 
accessible location. 
Für Installationen mit einem Stromkabel 
muß die Steckdose an einem Standort 
installiert werden, welcher einfachen 
Zugang erlaubt.
 
CAUTION: A 10A, 2-pole, ganged 
disconnect device, which also provides 
short circuit and overload protection, 
and has a minimum 3mm open circuit 
clearance, in accordance with the 
National Electric Code and applicable 
local codes must be installed by a 
licensed electrician at a location readily 
accessible to the equipment. 
Ein 10A, 2-poliges, gekoppeltes 
Ausschaltgerät, welches auch über 
einen Kurzschluß- sowie 
Überbelastungsschutz verfügt, und 
einen minimum 3mm offenen 
Schaltabstand aufweist, nach 
Übereinstimmung mit den Nationalen 
Elektrischen Regelungen sowie 
lokalen Regeln, muß an einem 
Standort installiert werden, welcher 
einfachen Zugang zum Gerät erlaubt.