Tyco Safety Products/Sensormatic AMS9050 Manuel D’Utilisation

Page de 31
Preliminary 
System Setup 
1.  Ensure controller power is off. 
2.  Connect antenna cables to the controller 
according to how the antennas are intended to 
perform. Refer to diagrams and tables on pages 
3 and 4 of this guide. See examples of pedestal 
installations in the antenna installation guide. 
3.  Set DIP switches S1 and S2 in the controller for 
the pedestal type, number of pedestals, and the 
antenna configuration used (see page 5). 
4.  Turn on the laptop computer and launch the 
ADS 4 service configurator. 
Note:
 For instructions on how to use configurator 
settings, click Help on the configurator. 
IMPORTANT!
 Ensure the controller power is off. 
Never restart or boot up a computer connected to 
an active controller. Doing so disables the mouse 
function on the computer. 
5.  Turn on the controller and connect the laptop 
computer to the service port. 
6.  Using the “Setup” page on the configurator: 
a.  Check that antenna selections match 
antennas physically installed. If not, check 
antenna connections to the controller. 
b.  Setup parameters for lamps, audio, relays, 
and remote alarms. 
7.  Using the “Tx Configuration” page, set Tx 
current for each antenna and enable/disable 
transmitters, if necessary. 
8.  Pass an active security tag by each antenna to 
verify antenna performance. Refer to Help if 
monitoring or adjustments are necessary. 
Verifying Operation 
Check that the antenna alarm lamp lights when a 
tag/label is passed through the checkout aisle, or if 
the system is covering adjacent aisles, that the 
lamp lights only in the aisle the tag/label was in. 
If the pick rate is acceptable, installation is 
complete. Reattach the top cover. 
AMC-7000 INTEGRATED METAL Foil DETECTION 
8200-2609-01, REV. 3a 
INSTALLATION GUIDE 
12 OF 31