Tyco Safety Products/Sensormatic AMS9050 Manuel D’Utilisation

Page de 31
Preliminary 
AMC-7000 INTEGRATED METAL Foil DETECTION 
8200-2609-01, REV. 3a 
INSTALLATION GUIDE 
30 OF 31
 
Specifications 
Electrical 
Power Supply 
Primary Input: ............................. 12V DC (-4V;+8V) 
Power Req. ..................................................... < 3W 
Relays 
Contact Form:.................................................DPDT 
Rated Load:............ 0.5A at 125VAC; 1A at 30VDC 
Max. Operating Voltage:............. 125VAC; 110VDC 
Max. Switching Capacity: ................... 62VA or 33W 
Min. Permissible Load ..................... 10μA;10mVDC 
Tx/Rx Input 
V
inp
 (max):.....................................................120V
o-p
 
I
inp
(max): ............................................... 18A
o-p
;5A
rms
 
Environmental 
Operating Temperature:.. 0° to 50°C (32° to 122°F) 
Non-operating Temperature....-40° to 70°C (-40° to 
158°F) 
Relative Humidity: .......... 0 to 90% non-condensing 
Enclosure Rating ..............................................IPX0 
Mechanical 
Metal Foil Detection Enclosure 
 
Length............................................ 28.3cm (11 1/8”) 
Width ............................................... 17.5cm (6 7/8”) 
Height ................................................ 8.6cm (3 3/8”) 
Weight ..........................................1.8kg (3bs. 14oz) 
Declarations 
 
Regulatory Compliance 
EMC ...............................................47 CFR, Part 15 
 
 
Safety.................................................... UL 60950-1 
 
CSA C22.2. 60950-1 
 EN 
60950-1 
 
REGULATORY PRODUCT NAME:  
AMC-7000 = TYPE: AMC-7000 
EQUIPMENT MODIFICATION CAUTION: Equipment 
changes or modifications not expressly approved by 
Sensormatic Electronics Corporation, the party responsible for 
FCC compliance, could void the user's authority to operate the 
equipment and could create a hazardous condition. 
See “Note: There may be installation restrictions on antennas 
in certain countries. See antenna installation guides for 
 
 
r, 
restrictions, if any. 
Regulatory Restriction:
 This device is
only intended to be installed as described 
in the installation guide. 
-  Because customer requirements dictate the 
placement of system components, your 
Sensormatic representative will supply this 
information separately. 
-  If this product was installed in a European 
Union or European Free Trade Association 
member state, please give the Declaration of 
Conformity included with this product to the 
manager or user. By law, this information must
be provided to the user. 
-  Because of the number of antennas and 
accessories that can connect to this controlle
methodically install this system to avoid 
problems. See “System Setup” in this guide fo
guidance on how to setup antennas.