Tyco Safety Products/Sensormatic BIC4170 Manuel D’Utilisation
BIS-4170 IVS PEOPLE COUNTER
8200-2702-01, REV. 4A
INSTALLATION AND PLANNING GUIDE
8 of 23
Running the Cables
Run a Cat5 cable from the installation site for the IVS device to the installation site for the PoE. Run another
cable from the PoE to the store’s computer wiring room.
cable from the PoE to the store’s computer wiring room.
Note: Cat5 cable runs cannot exceed 100m (330ft) without using a repeater. Terminate cables following Error!
Reference source not found. below.
• Use plenum / non-plenum cable per local requirements.
• Use pre-manufactured patch cables when available.
• Leave a sufficient service loop at end of each home run.
• Test all cables. Most on-site issues are cable related.
Reference source not found. below.
• Use plenum / non-plenum cable per local requirements.
• Use pre-manufactured patch cables when available.
• Leave a sufficient service loop at end of each home run.
• Test all cables. Most on-site issues are cable related.
Table 1. Ethernet cable pin assignments
Pin
Wire Color
1
WHT / ORG
2 ORG
3
3
WHT / GRN
4 BLU
5
5
WHT / BLU
6 GRN
7
7
WHT / BRN
8 BRN
Note: Male plug pin assignments are according to the T-568B standard. All connections are “straight through” from plug to
plug, that is: pin 1 to pin 1, pin 2 to pin 2, and so on.
plug, that is: pin 1 to pin 1, pin 2 to pin 2, and so on.
Pin 1