BIS-4170 IVS PEOPLE COUNTER 
8200-2702-01, REV. 4A 
INSTALLATION AND PLANNING GUIDE 
9 of 23
 
Mounting the IVS Device 
The IVS device can be installed at heights up to 4.3m (14ft) using one of the following methods: surface 
mounting bracket or recessed mounting bracket. 
WARNING! 
Install the IVS device in an air space not used for environmental air. DO NOT install in a 
plenum or other environmental air-handling space. 
WARNING! 
The ceiling must support up to 5.1kg (11.2 lbs).
 
If the ceiling cannot support the IVS 
device, ask building maintenance to install additional ceiling supports  
WARNING! 
The IVS device can mount to wood or drywall ceilings with minimal disturbance to the 
ceiling. It can also mount to grid ceiling structure but not to the removable tile itself  
Tested to IEC 60950-1. 
CAUTION: Double check all IVS device locations before drilling or cutting ceiling. This is especially 
important for multiple IVS devices 
Parts Supplied 
Customer to supply 1/4-20 threaded rod, two 1/4-20 nuts, 2x4 wood brace, and tile hold-down clips. 
!
!
!