18.5  Cross Zoning
Caution must be taken when cross zoning devices to ensure that the Cross Zone Time is long enough to allow a
trip of both zones before it expires. A Cross Zone Time that is too short may allow a trip of the zones and only a
zone fault report be sent to the Central Station.
When a Cross Zoned zone trips, a FAULT report is sent to the SCS-1R or SCS-VR Receivers. When two Cross Zoned
zones trip within the Cross Zone Time, both zones send ALARM signals to the receiver. For example, if zones 1
and 2 are Cross Zoned zones, and only zone 1 trips, a FAULT report is sent to the receiver for zone 1. If zone 1
trips and zone 2 trips within the Cross Zone Time, an ALARM report is sent to the receiver for zone 1 and zone 2.
Note: To operate correctly, all cross-zone zones need to be programmed as the same zone type.
18.6  Z-Wave Information
The CellComSLCZ is a security enabled Z-Wave product and is designed to be used as a primary controller.
The XFER feature allows an existing 3rd party network to be transferred into the CellComSLCZ.
The CellComSLCZ can support Z-Wave products from different vendors and product categories. It is
recommended to use devices listed on the buy.dmp.com site for best performance.
Z-Wave terminology:
•   Inclusion is the process of adding a device to the Z-Wave network. The new device is ‘included’ into the
Z-Wave network.
•   Exclusion is the process of removing a device from the Z-Wave network. The new device is ‘excluded’ from
the Z-Wave network.
•   Replication is the process of copying network information to another device (typically a Z-Wave controller) in
the Z-Wave network.
18.7  Zone 4 Bell Cadence Information
The CellComSL Series evaluates the first 3.5 seconds of bell cadence timing to detect the type of alarm sent.
Bell cadence types are:
BELL CADENCE 
ZONE NUMBER 
TYPE OF MESSAGE
 
Steady 
ZONE 4 
BURGLARY
  Pulse or Temporal 3 
ZONE 5 
FIRE
 
Temporal 4 
ZONE 6 
EMERGENCY OR
 
 
 
CARBON MONOXIDE
Figure 16: Zone 4 Bell Cadence Information
Steady
Pulse
Temporal 3
Temporal 4
1.0 sec.
1.0 sec.
1.0 sec.
1.0 sec.
1.0 sec.
.5 sec.
.5 sec.
.5 sec.
1.5 sec.
.5 sec.
.5 sec.
.5 sec.
.5 sec.
3.5 sec.
Each .1 sec. On
5.0 sec.
On
Off
On
Off
On
Off
On
Off
Each .1 sec. Off
Each .1 sec. On
Each .1 sec. Off