Honeywell International Inc. 8DL5800PIR-OD Manuel D’Utilisation
5800-OD Wireless Outdoor Motion Sensor – Installation Instructions
–
5
–
TROUBLESHOOTING
SYMPTOM
CAUSE
REMEDY
Alarms when no one is walking
through the detection area.
through the detection area.
Sensor is not perpendicular to ground.
Remount and align sensor so the detection area is parallel to
the ground.
the ground.
Sensor is detecting moving trees,
bushes, or a strong source of light.
bushes, or a strong source of light.
Check for moving trees, or bushes or a strong light source.
Perform a Settings & Adjustments procedure.
Perform a Settings & Adjustments procedure.
Lower detection area is too long.
Set Detection Length to a shorter range.
A heat source in the area may be
causing an abrupt temperature
change.
causing an abrupt temperature
change.
Move or remove the heat source.
Mask the area pointing to the source of heat, or shorten the
Detection Length.
Mask the area pointing to the source of heat, or shorten the
Detection Length.
COMPONENT IDENTIFICATION
Mounting Screws
T4 x 20
T4 x 20
Detector
Sensor
(Do not touch)
(Do not touch)
Cover
LED
Indicator
Indicator
Cover
Lens
Back Box
M4 x 30 (4 places)
Captive
Lock Screw
Lock Screw
Masking Strip
(Use as required)
(Use as required)
Lens
Holder
Holder
UP
DIP Switch
Sensitivity Select
Switch
Switch
Detection Length
Ajustment Switch
Ajustment Switch
Pole
Bracket
Bracket