Honeywell International Inc. 8DL5800PIR-OD Manuale Utente

Pagina di 6
 5800-OD Wireless Outdoor Motion Sensor –  Installation Instructions 
 
– 
5
 – 
TROUBLESHOOTING 
SYMPTOM
 
CAUSE
 
REMEDY
 
Alarms when no one is walking 
through the detection area. 
Sensor is not perpendicular to ground. 
Remount and align sensor so the detection area is parallel to 
the ground. 
 
Sensor is detecting moving trees, 
bushes, or a strong source of light. 
Check for moving trees, or bushes or a strong light source.  
Perform a Settings & Adjustments procedure.  
 
Lower detection area is too long. 
Set Detection Length to a shorter range. 
 
A heat source in the area may be 
causing an abrupt temperature 
change. 
Move or remove the heat source. 
Mask the area pointing to the source of heat, or shorten the 
Detection Length.  
 
 
COMPONENT IDENTIFICATION
 
 
 
Mounting Screws
T4 x 20
Detector
Sensor
(Do not touch)
Cover
LED
Indicator
Cover
Lens
Back Box
M4 x 30 (4 places)
Captive
Lock Screw
Masking Strip
(Use as required)
Lens
Holder
UP
DIP Switch
Sensitivity Select
Switch
Detection Length
Ajustment Switch
Pole
Bracket