SharpEye™ SCV & SxV X-Band Radome Radar 
Chapter 7: Termination 
 
KH-1650-CA issue 1 
Page 31 of 60 
Termination 
7.1  Cabling and termination 
CABLING 
  Cabling, terminations and connections are to be made as per the latest version of IEE wiring 
regulations BS-7671, Requirements for Electrical Installation. 
  Cables are to be of correct specification and rating and should be run in suitable cable trays or 
guides. They should be laid in positions that cannot cause an obstruction or hazard.
 
 
Cable runs must allow for service loops.
 
 
All cables should be secured in position using cable ties placed at regular intervals.
  
 
In order to reduce electromagnetic interference effects, all cables should be routed as directly as 
possible, consistent with consideration for other equipment.  
 
Cables should not be installed close to high-power lines such as radio-transmitter lines. 
 
Crossing of cables should be done at right angles (90°) to minimize magnetic field coupling. 
  Cables must be laid and secured in a fashion that does not place undue stress or strain on the 
cable or the connector. Ensure excessive strain is not applied to the cable or the connecters when 
connecting and disconnecting the DC power and LAN cables.  
  Provision must be made on the mounting platform for securing of the cables.  
 
MINIMUM BEND RADIUS 
The minimum bend radius of the cable must be observed when laying the cable. Where a bend radius 
is not stated, a minimum bend radius of 12 x the cable diameter should be assumed for Kelvin 
Hughes Ltd supplied cable.  
 
 
 
 
 
CORRECT 
A cable correctly laid taking the 
minimum bend radius into account.
 
INCORRECT 
Cables incorrectly laid with the bend below the minimum bend radius 
which places strain on the cable and connector.
 
Drawings shown are for reference use only and do not represent a scaled drawing of the minimum bend radius. 
 
CONNECTION/ CONNECTOR NOTES 
  Fully isolate all sources of power to the system before mating and de-mating any connectors. 
  Installation of external connectors should only be undertaken in dry conditions.  
  Connectors should be inspected immediately prior to installation to ensure that pins are not bent, 
corroded or otherwise damaged and that no contamination, pollution or moisture has entered 
either mating half. Where required, cleaning should be undertaken carefully, in such a way as not 
to damage the contacts or insulation. For example to remove contamination and moisture 
compressed air spray may be used in accordance with manufacturer's and local guidance along 
with nylon brushes. 
  The protective caps on the SCV/ SxV connectors are retained and must be left attached to the 
system for future use.  
  The connecter must never be left disconnected and exposed to the elements. 
  The pre-terminated connectors are keyed to prevent incorrect connection. 
  When fitted ensure each connector is fully inserted and makes a full waterproof seal. 
  Ensure the cable restraining method does not strain the connector as this could cause the 
connector to become damaged.  
  Ensure excessive strain is not applied to the cable or the connecters when connecting and 
disconnecting the DC power and LAN cables.