Kelvin Hughes Limited SXV-A1 Manuel D’Utilisation
SharpEye™ SCV & SxV X-Band Radome Radar
Chapter 7: Termination
KH-1650-CA issue 1
Page 33 of 60
7.2 DC input
SCV-A167-**
Note 1 & Note 2
A pre-terminated cable can be supplied for
connecting the DC input to PL1 located on the
base of the SCV/ SxV radome radar.
CABLE LENGTH
Standard systems typically use 10 metres of
cable however other cable lengths are available
as detailed below.
Part No.
Note 2
Length (mm)
SCV-A167-05
5000
SCV-A167-10
10000
SCV-A167-15
15000
SCV-A167-20
20000
SCV-A167-25
25000
SCV-A167-30
30000
Any additional cabling required for connecting the system to the DC power, breakers etc. should be of
a sufficient gauge to ensure that the minimum voltage required by the SCV/ SxV is maintained under
the worst case load conditions (see section 13.3).
CABLE TYPE
LSZH 3x14AWG Screened. Diameter approx. 11mm.
CONNECTOR TYPE
Fischer UltiMate UP01L13 F303S BK1 Z1ZB (SCV/SxV Mating half UR02W13 M303S BK1 E1AB)
DC POWER SOURCE
The SharpEye
TM
SCV/
SxV series has been designed to run from a +24VDC to +30VDC supply, with
+28VDC being used in typical installations.
For longer cable runs higher DC supply voltages are recommended. Please refer to section 13.3 for
details and full electrical specifications.
WARNING
The SCV/ SxV must not be connected directly to an unprotected/ un-switched DC power source.
Isolate all of DC power to the system before mating or de-mating the connectors.
NOTICE
Connectors should be inspected prior to connection to ensure there are no foreign object or damage
to the connector.
Note 1: Where -** is the length of the cable in metres.
Note 2: SCV variant SCV-A1-10-ADAC should be ordered with power cable SCV-A177-** rather
than SCV-A167-**.
Please contact Kelvin Hughes Ltd if alternative cable assemblies are required.
Note 3: DC circuit breakers and switches are not supplied.
DC input
connection