Chapter 7: Termination 
 
KH-1650-CA issue 1 
Page 33 of 60 
7.2  DC input 
 
SCV-A167-** 
Note 1 & Note 2
 
A pre-terminated cable can be supplied for 
connecting the DC input to PL1 located on the 
base of the SCV/ SxV radome radar. 
 
CABLE LENGTH 
Standard systems typically use 10 metres of 
cable however other cable lengths are available 
as detailed below.
 
 
 
 
Part No. 
Note 2
 
Length (mm) 
SCV-A167-05 
5000 
SCV-A167-10 
10000 
SCV-A167-15 
15000 
SCV-A167-20 
20000 
SCV-A167-25 
25000 
SCV-A167-30 
30000 
 
Any additional cabling required for connecting the system to the DC power, breakers etc. should be of 
a sufficient gauge to ensure that the minimum voltage required by the SCV/ SxV is maintained under 
the worst case load conditions (see section 13.3). 
 
CABLE TYPE 
LSZH 3x14AWG Screened. Diameter approx. 11mm. 
 
CONNECTOR TYPE 
Fischer UltiMate UP01L13 F303S BK1 Z1ZB (SCV/SxV Mating half UR02W13 M303S BK1 E1AB) 
 
DC POWER SOURCE 
The SharpEye
TM 
SCV/
 
SxV series has been designed to run from a +24VDC to +30VDC supply, with 
+28VDC being used in typical installations. 
For longer cable runs higher DC supply voltages are recommended. Please refer to section 13.3 for 
details and full electrical specifications.
   
WARNING 
The SCV/ SxV must not be connected directly to an unprotected/ un-switched DC power source. 
Isolate all of DC power to the system before mating or de-mating the connectors. 
 
NOTICE 
Connectors should be inspected prior to connection to ensure there are no foreign object or damage 
to the connector. 
 
 
 
 
 
 
Note 1:   Where -** is the length of the cable in metres. 
Note 2:   SCV variant SCV-A1-10-ADAC should be ordered with power cable SCV-A177-** rather 
than SCV-A167-**.  
Please contact Kelvin Hughes Ltd if alternative cable assemblies are required. 
Note 3:   DC circuit breakers and switches are not supplied. 
DC input 