Kelvin Hughes Limited SXV-A1 Manuel D’Utilisation
SharpEye™ SCV & SxV X-Band Radome Radar
Chapter 7: Termination
KH-1650-CA issue 1
Page 36 of 60
7.4 Ground/ Earth cable
SCV-A145 EARTH BONDING CABLE
The earth strap supplied in the fitting kit MUST be used to fix the SCV/SxV to a proven earth point on
the mounting platform using the fixings supplied with the unit.
CABLE LENGTH
250mm long.
Other cable lengths are available, Please contact Kelvin Hughes Ltd for further details.
CONNECTION
The SCV/SxV is grounded via the M6 earth stud
located on the base of the SCV/SxV which should
be connected to a tested/ proven ground point.
For EMC/ interference reasons, Kelvin Hughes
Ltd recommend that the earth/ ground connection
is always connected to the common platform
chassis ground.
NOTICE
The ground/ earth termination MUST BE MADE using the SCV-A145 cable supplied in the fitting kit
Please contact Kelvin Hughes Ltd if alternative grounding arrangements are required.
BATTERY CONNECTION
SxV systems powered by a battery do not require an earth connection.
CABLE DETAILS
Example of standard SCV-A145 cable
CABLE SPECIFICATION
Cable
Length
Conductor
CSA (mm
2
)
Stud size
ref.
Hole Ref.
(diameter)
Lug
width
Lug
thickness
Current
rating
250
Note
15
M6
6.4
15.5
2.2
120A
M6 earthing
stud