7.4  Ground/ Earth cable 
 
SCV-A145 EARTH BONDING CABLE 
The earth strap supplied in the fitting kit MUST be used to fix the SCV/SxV to a proven earth point on 
the mounting platform using the fixings supplied with the unit.  
 
CABLE LENGTH 
250mm long.  
Other cable lengths are available, Please contact Kelvin Hughes Ltd for further details. 
 
CONNECTION 
The SCV/SxV is grounded via the M6 earth stud 
located on the base of the SCV/SxV which should 
be connected to a tested/ proven ground point.  
 
For EMC/ interference reasons, Kelvin Hughes 
Ltd recommend that the earth/ ground connection 
is always connected to the common platform 
chassis ground. 
 
 
 
 
NOTICE 
The ground/ earth termination MUST BE MADE using the SCV-A145 cable supplied in the fitting kit 
Please contact Kelvin Hughes Ltd if alternative grounding arrangements are required. 
BATTERY CONNECTION 
SxV systems powered by a battery do not require an earth connection. 
 
CABLE DETAILS 
 
Example of standard SCV-A145 cable 
CABLE SPECIFICATION 
Cable 
Length 
Conductor 
CSA (mm
2
Stud size 
ref. 
Hole Ref. 
(diameter) 
Lug 
width 
Lug 
thickness 
Current 
rating 
250 
Note
 
15 
M6 
6.4 
15.5 
2.2 
120A 
 
 
 
M6 earthing 
stud