12.3  Troubleshooting 
 
Loss of video 
 
and/ or 
 
Loss of status 
messages 
If video ceases to be displayed and the SCV/ SxV is installed in a position 
where a person can be within 15m of the antenna, as a precautionary measure 
the operator should cease transmission immediately and investigate the 
problem. 
 
Transmission can be stopped by switching the SCV/ SxV system OFF. This 
ensures that if the antenna has ceased rotation under fault conditions in such a 
position that it is facing a person and further software faults occur, nobody is 
accidentally irradiated in excess of the safe limits. 
If the system fails to communicate after the initialisation period, isolate the 
power to the system and ensure that both the DC and LAN cables are securely 
connected and free from damage. 
 
Check that the DC voltages being supplied to the system are within acceptable 
limits. If the system randomly resets or is temporarily unavailable, check that the 
DC input to the system is stable under load conditions and does not drop below 
the recommended minimum DC input level noted in section 13.3. 
 
Standard network diagnostic tools and software may be used to ensure data is 
being output from the SCV LAN connection. If the system operates on a 
network, try connecting the SCV directly to the display from the LAN cable or 
diagnostic tools. 
System 
showing 
Video and/ or 
status 
messages but, 
interference or 
poor returns 
are present on 
the display 
sub-system 
Ensure that there are no objects in the immediate vicinity of the system that 
may be blocking or reflecting RF radiation back towards the radome. If this is 
unavoidable, ensure that a blanking sector has been correctly configured to 
cover the affected area (please refer to section 4 regarding blanking sectors). 
 
It may be necessary to cover the objects with Radar Absorbent Material (RAM) 
to attenuate unwanted reflections. 
 
Where the display software permits: 
1.  Change the SharpEye™ transmission frequency. If the problem disappears 
it may be being caused by interference from other transmitters in the local 
vicinity. 
 
2.  Change the SharpEye power from High to Low power. Return the system to 
High power on completion of any tests. 
 
3.  Mute the system on each available range mode and see if any interference 
remains on screen.  If a mute feature is not available, set a blanking sector 
that covers the area of interference or the whole display are (i.e. 360°). 
Fault reporting 
If a problem persists and cannot be resolved, please contact Kelvin Hughes Ltd 
with  the following details: 
1. 
FAULT CONDITION: Describe the condition being experienced, the modes 
or control commands that cause the issue and any error messages that 
have been observed. 
 
2. 
BIT DATA: If the communications interface in use can display BIT data from 
the SCV/ SxV, please advise the messages being displayed. A full list of BIT 
data is available from Kelvin Hughes upon request. 
 
3. 
SCREEN GRABS: Where permissible and where the display software 
permits, take screen shots of the display showing the affected video. If there 
is no screen grab facility take a photograph or a short video. Photographs or 
diagrams of the installation, where permissible, may also prove useful. 
 
4. 
INTERFERENCE: If the issue relates to an object that cannot be observed 
on screen, describe the object, its distance from the radar and any other 
conditions (e.g. metrological) that may have an impact on target detection.