Spacelabs Healthcare Inc. 76A90343-WMTS Manuel D’Utilisation
SPECIFICATIONS
Ultraview
Digital
Telemetry
90343,
90347,
90478-Q,
90478-T,
90478-V,
90479-A
Digital
Telemetry
90343,
90347,
90478-Q,
90478-T,
90478-V,
90479-A
Spacelabs Medical, Inc.
15220 N.E. 40th Street
P.O. Box 97013
Redmond, WA 98073-9713
(425) 882-3700
15220 N.E. 40th Street
P.O. Box 97013
Redmond, WA 98073-9713
(425) 882-3700
Ultraview, Ultraview Care Network,
PCMS, and Multiview are trademarks of
Spacelabs Medical, Inc.
PCMS, and Multiview are trademarks of
Spacelabs Medical, Inc.
Other brands and product names are
trademarks of their respective owners.
trademarks of their respective owners.
All specifications are subject to change
without notice.
without notice.
© Spacelabs Medical, Inc. 2000
061-0801-00 Rev. D 9/2000
ACCESSORIES
Please refer to the Spacelabs Medical Supplies
Catalog for availability of ECG lead wires and
electrodes, blood pressure cuffs, and SpO
electrodes, blood pressure cuffs, and SpO
2
sensors from Spacelabs Medical
90343/90347 Transmitter Pouch
Part Number: 015-0500-00
DIN Standard Safety ECG Lead Wire Set (5 wire)
24
”
snap
Part Number: 012-0605-00
Receiver Housing Protective Cover
Part Number: 200-0180-00
Whip Antenna (UHF)
Part Number: 117-0040-00
Belt Clip
Part Number: 344-0020-00
SpO
2
Adapter Cable (Nellcor)
Part Number: 700-0014-00
ABP Telemetry Adapter Cable
Part Number: 700-0015-00
ABP Pouch
Part Number: 015-0501-00
ABP Shoulder Strap
Part Number: 016-0262-00
ABP Waist Belt
Part Number: 016-0080-00
ABP Report Management System
Part Number: 90121
ABP Report Management System Adaptor Cable
Part Number: 012-0097-02
ABP Adult Adapter Assembly
Part Number: 714-0017-00
NELLCOR SpO
2
SENSOR ACCURACY
AND SENSOR SELECTIONS
Nellcor Reusable SpO
2
Sensors —
Finger Clip (DS-100A) (P/N 690-0003-00)
70–100%,
±
3% absolute saturation
OXIBAND A/N (OXI-A/N) (P/N 690-0004-00)
70–100%,
±
3% absolute saturation
OXIBAND P/I (OXI-P/I) (P/N 690-0039-00)
70–100%,
±
3% absolute saturation
Nellcor Disposable SpO
2
Sensors —
Adult (N-25) (P/N 690-0006-00)
70–100%
±
2% absolute saturation
Neonatal (N-25) (P/N 690-0006-00)
70–100%
±
3% absolute saturation
Pediatric (D-20) (P/N 690-0007-00)
70–100%
±
2% absolute saturation
Adult (D-25) (P/N 690-0001-00)
50–69%
±
3% absolute saturation
70–100%
±
2% absolute saturation
Nasal (R-15) (P/N 690-0005-00)
80–100%
±
3.5% absolute saturation
Infant (I-20) (P/N 690-0002-00)
50–69%
±
3% absolute saturation
70–100%
±
2% absolute saturation
1
Operational service life (in hours) assuming a new
alkaline battery (minimum 580 mAH capacity) or
lithium battery (minimum 1200 mAH capacity) used
until the local low battery indicator begins to flash.
alkaline battery (minimum 580 mAH capacity) or
lithium battery (minimum 1200 mAH capacity) used
until the local low battery indicator begins to flash.
2
NIBP operations from a 90217 ABP Monitor sending
readings to the 90343 Multi-parameter telemetry
transmitter. The 90217 ABP monitor will inflate a
standard size adult cuff at least 240 times with alkaline
batteries.
transmitter. The 90217 ABP monitor will inflate a
standard size adult cuff at least 240 times with alkaline
batteries.
Table 1: Transmitter Battery Service Life
1
(hours)
Battery
Type
Type
9 Volt Alkaline (ANSI/NEDA 1604A)
9 Volt Lithium (ANSI/NEDA 1604LC)
Load
Con-
ditions
Con-
ditions
2
ECG
Only
Only
ECG
and
Con-
tinuous
SpO
and
Con-
tinuous
SpO
2
ECG and
2 minute
Episodic
SpO
2 minute
Episodic
SpO
2
ECG and
5 minute
Episodic
SpO
5 minute
Episodic
SpO
2
ECG and
30 minute
Episodic
SpO
30 minute
Episodic
SpO
2
and
NIBP
ECG
Only
Only
ECG
and
Con-
tinuous
SpO
and
Con-
tinuous
SpO
2
ECG
and 2
minute
Episodic
SpO
and 2
minute
Episodic
SpO
2
ECG
and 5
minute
Episodic
SpO
and 5
minute
Episodic
SpO
2
ECG
and 30
minute
Episodic
SpO
and 30
minute
Episodic
SpO
2
90343
48
24
36
38
40
120
60
100
104
106
90347
52
Not
Applicable
Applicable
Not
Applicable
Applicable
Not
Applicable
Applicable
Not
Applicable
Applicable
132
Not
Applicable
Applicable
Not
Applicable
Applicable
Not
Applicable
Applicable
Not
Applicable
Applicable
Medical telemetry spectrum allocations may be assigned to frequencies already allotted to other priority
users. This means that telemetry operations may be exposed to radio frequency interference that may
disrupt or impede telemetry patient monitoring. Additionally, medical telemetry spectrum allocations
may be changed by government action and Spacelabs Medical accepts no responsibility for such
changes, including the possibility that the product may not operate in the modified permissible
spectrum ranges other than those expressly set forth in Spacelabs Medical’s published product data
sheets. Spacelabs Medical cannot, and does not, guarantee interference-free telemetry operation.
users. This means that telemetry operations may be exposed to radio frequency interference that may
disrupt or impede telemetry patient monitoring. Additionally, medical telemetry spectrum allocations
may be changed by government action and Spacelabs Medical accepts no responsibility for such
changes, including the possibility that the product may not operate in the modified permissible
spectrum ranges other than those expressly set forth in Spacelabs Medical’s published product data
sheets. Spacelabs Medical cannot, and does not, guarantee interference-free telemetry operation.