Rothenbuhler Engineering Company Inc 1673-1 Manuel D’Utilisation
1673 OPERATION MANUAL REV A
35
Figure 4-6 Status Check Results on Controller
Figure 4-6 are the results of our STATUS check with all 8 Remote Units reporting. The
steady green READY lights for Remote Units #1-8 indicate they are disarmed. The steady yellow
BATT lights indicate Remote Units #1-8 do not have low batteries.
BATT lights indicate Remote Units #1-8 do not have low batteries.
Figure 4-7 Arm the SELECTED Remote Units
4.2.8.
Wait for the appropriate warning sirens. About 30 seconds from firing, press and hold
the ARM switch for ½ second. The red ARMED lights will blink for up to 15 seconds and come on
steady as shown in Figure 4-7.