Checkpoint Systems Inc. FISOLRR Manuel D’Utilisation

Page de 36
1-26
I L S   O p e n   P l u s   3 . 0   I n s t a l l a t i o n   M a n u a l
The distance from tag to tag should be greater than 10 cm (3.9”). If the tag to tag 
distance is reduced, the gate distance GD must be reduced correspondingly. This 
applies in particular to distances under 5 cm (2”).
The maximum number of tags (serial number or data) depends on the traverse speed 
with which the tags are brought through the capture area of the gate. The number of 
tags may be increased in the gate distance GD is correspondingly reduced and the 
maximum speed adjusted accordingly.
The antenna should be at least 50 cm (19.7”) from metal parts.
There should be no interference of the Reader from other electrical devices in the 
environment. The noise level difference should be less than 20 mV. 
The ID ISC.LR200-B Reader should be set to an RF power of 8 watts. 
When using ISO 15693 transponders, the Readers should be set 
Technical Data
Antenna, Master and Slave.
* Persistent deformation after load release approx. 0.5 cm (.2”).
Table 1.1
Mechanical Data
Type
Description
Housing
UV stabilized ABS
Dimensions (W x H x D)
760 x 1700 x 80 mm 
± 
5mm
 
(300” x 670” x 31.5”) 
± 
2” 
Weight
• ID ISC.ANT1400/760-C
• ID ISC.ANT1400/760-B
approx. 35 kg (incl. Reader)
approx. 33 kg
Enclosure Rating
IP 54
Color
• Antenna Body
• Upper and lower covers
Metallic light gray
Slate gray similar to RAL7015
Mounting
• No. of attaching points
• Recommended anchors
• Recommended minimum load capacity of the 
floor fastener
4
∅ 
8  mm
5000 N / anchor
Maximum horizontal load on the top edge of 
the antenna
250 N*
Table 1.2
Electrical Data****
Type
Description
Supply Voltage
12 - 24 V DC to the entire gate
7 - 12 V DC to the antenna board
Current Draw
max. 150 mA (DC)
Maximum transmitting power per antenna
10 W