Table 1008.   Directional Antenna Test Procedure (cont)
(3) Return to the main menu by pressing the MAIN soft key. Set start frequency F1 and 
stop frequency F2 as follows:
(a) The Site Master is capable of storing ten setup’s. The above setup is complete and 
can be saved for future use. Refer to the User’s Guide for information on saving 
and recalling setup a specific setup.
(b) Press FREQ soft key.
(c) Press FI soft key and use the keyboard to enter the numerical value 995, then 
press ENTER when data entry is complete.
(a) Press F2 soft key and use the keyboard to enter the numerical value 1124 then 
press ENTER when data entry is complete.
(b) Check that the FREQ (MHz) scale in the display area indicates the above start and 
stop values.
(4) Set the marker frequencies as follows:
(c) Press MKRS soft key and M1 twice. Use the keyboard to enter the numerical value 
1030 and press ENTER
(d) Press MKRS soft key and then press M2 twice. Use the keyboard to enter the 
numerical value 1090 and press ENTER.
(e) Check that the marker frequencies in MHz, indicates M1=1030 and M2=1090.
4.
Performance Calibration
A. General
(1) The calibration should be performed in the same environment as the actual test. Like 
most electronic test equipment, the Site Master S331 is temperature sensitive. If the 
temperature changes a few degrees, a warning indicator will appear on the left-hand 
edge of the LCD screen. If the temperature indicator appears, the Site Master S331 
should be calibrated again to improve the accuracy of the readings.
Table 1.   Site Master Setting
Soft key
Setting
Soft key
Setting
B1:
Mode= SWR
B5:
UNIT=ENGLISH
B2:
LIMIT BEEP OFF
B6:
FIXED CW OFF
B3:
KEYBD LOCK OFF
B7:
PRINTER=NOTE
B4:
SINGLE SWP OFF