Table 1008. Directional Antenna Test Procedure (cont)
B. Procedure
(1) Remove the adapter cable (part number 965RFTS-201) from the hard case and
connect it to the Site Master S331 test port.
NOTE: All connections should be finger tight. DO NOT OVER TIGHTEN OR USE
PLIERS.
(2) Select the SMA jack to "N" Jack adapter (part number NS010, see Figure 1) from the
hard case and connect the SMA plug end of the adapter cable.
Figure 1. RF Trouble Shoot Adapter Kit Layout
(3) Perform a measurement calibration by pressing the START CAL on to keyboard.
(4) Select the desired location to store the calibration, CAL A or CAL B, by using the
Up/Down Arrow
key. Place the > symbol adjacent to the desired location and press the
ENTER key.