CTCSS N 
CDCSS N 
SQL CEN 
SQL LOW 
SQL HIGH 
5. Press [
] key to adjust the Transmit High Power, Transmit Low Power, Battery Reference Value, CTCSS Deviation 
(Wideband), CDCSS Deviation (Wideband), CTCSS Deviation (Narrowband), CDCSS Deviation (Narrowband), 
BUSY Reference Value (Center Frequency), BUSY Reference Value (Low Frequency) and BUSY Reference Value 
(High Frequency) individually. 
6. Press [
] key to exit from the Adjustment Mode and return to the menu of Test Mode. LCD displays  “ADJUST”. 
 
Adjusting Transmit High Power 
Use this procedure to adjust the transmit High Power level. 
1. Connect the power meter to the radio. 
2. Turn Channel Selector knob to select the setting option “HI POWER”. 
3. Transmission is performed automatically at High Power when the [
] key is pressed. After the frequency is displayed 
for one second, the display “HPWR XXX” now appears. (XXX=0 to 255) 
4. Turn the channel selector knob while observing the power meter to obtain the transmit power needed. Turn the 
channel selector knob clockwise for an increase in power, and counterclockwise for a decrease in power. 
5. Press [
] key to store the alignment value into the memory and return to the “LO POWER” display. Press [
] key to 
cancel the alignment value and return to the “HI POWER” display. 
Adjusting Transmit Low Power 
Use this procedure to adjust the transmit Low Power level. 
1. Connect the power meter to the radio. 
2. Turn Channel Selector knob to select the setting option “LO POWER”. 
3. Transmission is performed automatically at Low Power when the  [
] key is pressed. After the frequency is displayed 
for one second, the display “LPWR XXX” now appears. (XXX=0 to 255) 
4. Turn the channel selector knob while observing the power meter to obtain the transmit power needed. Turn the 
channel selector knob clockwise for an increase in power, and counterclockwise for a decrease in power. 
5. 
Press [
] key to store the alignment value into the memory and return to the “BATT REF” display. Press 
[
] key to 
cancel the alignment value and return to the “LO POWER” display. 
 
Adjusting the Battery Reference Value 
Use this procedure to adjust the reference value for issuing battery low voltage alarms. 
1. Using an external power supply feed in the reference value at which you wish to trigger the alarm. 
2. Turn Channel Selector knob to select the setting option “BATT REF”. 
3. Transmission is performed automatically at High Power when the [
] key is pressed. After the frequency is displayed 
for one second, the display “BATT XXX” now appears. (XXX=1 to 255).  
4. Adjust by turning the Channel Selector knob counterclockwise so that the red LED lights up and turning clockwise so